星际现金娱乐

服务热线: 400-666-2522 Chinese Station | ENGLISH Service Hotline: 400-666-2522

3nh brand color difference meter manufacturers

Leader of color detection industry FOCUS ON COLOR
Position : Home > Products > Standard light source box > TILO standard lighting source >
Products Recommended

Standard light source viewing stage CC120-E

Standard light source viewing stage CC120-E

Meets ISO 3664: 2009 industry lighting standard requirements,
Provide D65, D50, TL84, CWF and other light source options
Consulting Hotline: 400-666-2522
  • product description
  • Specifications
  • related software
I. Introduction to the standard light source CC120-E

The standard light source printing viewing platform is widely used in the printing field to accurately compare the color deviation of printed materials. Because different light sources have different radiant energies, they will appear different colors when irradiated onto the object.

In color management in printing production, although the inspectors have carefully compared the colors of the goods, but because the ambient light source is not standard or is inconsistent with the light source used by customers, the colors seen in different lights are different, and the color difference of the goods is not determined. accurate. When the customers inspect the goods, they will complain or even return the goods because the color difference exceeds the standard range, which seriously affects the company's goodwill.

To effectively solve the above problems, the most useful method is to verify the color of the goods under the same light source and controllable conditions. For example, in the international general standards, artificial daylight D65 is often used as the standard light source for evaluating the color of goods.

Especially at night time, it is very important to use standard light source to check the color deviation of the goods.

The printing test stand also provides D65, D50, TL84, CWF and other light source options, with the function of testing metamerism.

Second, the standard light source CC120-E operating instructions

1. Plug one end of the power cord into the sample stand into the power socket of the sample stand. The power socket of the sample stand is on the top of the light box, and the other end is connected to the mains power supply. Match).

2. Select a light source switch and press it. The corresponding light source tube lights up. At the same time, watch the timer of the sample platform to start timing. If you want to switch the light source, you can turn off the front light source, and then press the light source switch you want to light. To turn on two or more light sources at the same time, just press the two or more light source switches at the same time.

3. When the item to be tested is placed in the middle of the table and the colors of two or more items need to be compared, they should be placed side by side on the viewing platform and compared as much as possible in the middle. When working, the work surface should not be placed with debris that is not related to the work, so as not to affect the color change.

4. After the test is completed, turn off all the light source lamp tubes that have been turned on. Turn off the power when not in use during off hours, and unplug the power plug when not in use for a long time.

5. Replace the lamp with a new one. There are two white cap screws in front of the transparent glass of the light box. You can unscrew the two screws and then open the transparent glass. When you open the transparent glass, open it gently and lower it gently. Remove the lamp that needs to be replaced, and then install the new lamp. Pay attention to different light sources and different positions of the tube.

Third, the standard light source to see the sample table CC120-E daily use maintenance precautions

1. Use of standard light source: After the light source tube is lit for 30 minutes, the color temperature, color rendering index and illuminance reach the optimal state; if there is no special reason, avoid frequent switching and switching of the tube to extend the life of the tube.

2. Lifetime of the light source tube: After 2000-3000 hours of use of the standard light source tube, the color temperature, color rendering index, and illuminance will decay. It is recommended to replace it in time to avoid affecting the color matching effect.

3. Cleaning and maintenance: Please unplug the power plug and cut off the power before cleaning and maintenance. Please wipe the device with a regular detergent, and then wipe it with a clean and soft cloth. Do not rinse it directly with water.

Fourth, the standard light source CC120-E special precautions

Special note for viewing the sample stand

Five, the standard light source CC120-E simple troubleshooting

Light source does not light up 1. Whether the power cord is plugged in perfectly
2. The lamp holder may be loose and tighten.
3. Whether the lamp is damaged or burnt out, replace the lamp
Reflective dim Wipe with a clean, soft cloth
Light timer does not count Press the reset button and restart

Six, the standard light source CC120-E warranty statement

1. The light source products sold by the company are guaranteed for one year from the date the product reaches the customer company. If there is a product quality problem within one year, the company will be responsible for repair or replacement. Eight Warranty description

2. Our company's products have standard packaging. After receiving the goods, if you find that the packaging or the product inside is damaged, please contact us quickly so that we can handle it for you.

3. After the lamp is damaged, please replace the professional standard light source lamp. The company supplies a variety of original light source lamps for a long time.

4. If you have any questions about installation or use, please contact our technical engineers directly.

Introduction of standard light source CC120-E tube accessories

Artificial artificial light source for printing

1.D50 standard light source tube simulates Daylight warmer daylight

◆ High color rendering index CRI≥95 or CRI = 98

◆ Comply with ISO 3664: 2009 printing standard observation conditions

◆ Special light source for imported printing press to see the sample table, Graphic Pro, COLOR proof series

60cm 18W / 950 T8 Graphica Pro Imported from Europe
120cm 36W / 950 T8 Graphica Pro Imported from Europe
150cm 58W / 950 T8 Graphica Pro Imported from Europe

2.D65 standard light source tube simulates Daylight colder daylight

◆ High color rendering index CRI≥95 or CRI = 98

◆ Comply with ISO 3664: 2009 printing standard observation conditions

◆ Special light source for sample stage and color light box, T60 + P60 + CC120 series

60cm 18W / 965 T8 Graphica Pro Imported from Europe
120cm 36W / 965 T8 Graphica Pro Imported from Europe
150cm 58W / 965 T8 Graphica Pro Imported from Europe

Other commonly used light sources

CWF light tube (4150K, cool white fluorescent, American store light source)
84 light source tube (4000K, European and Japanese store lighting source)
U30 light tube (3000K, American store lighting source)
U35 light tube (3500K, designated light source by Target, USA)
Light source tube (Ultraviolet light source for products using fluorescent and whitening dyes)
A light bulb (2856K, American window spotlight / incandescent lighting for home, yellow reference light source)

Part One: 3NH Official Download

Part 2: Download the full range of color card electronic versions

Part III: Download of 3nh instrument instruction manual

Part 1: 3NH official download

PeColor color matching software download (update date: 9/15/2019)

iQstest Image Quality Comprehensive Test Software Download (Update Date: 7/18/2019)

Software download of SDQC host computer for spectrodensitometer (update date: 2019/7/19)

YS series host computer software SQCX download (update date: 2019/5/17)

NS808 spectrophotometer PC software simplified Chinese version

PC software for NS808 spectrophotometer

Spectrophotometer NS series host computer software SQC8 [Chinese, English, Traditional] (Update date: 2016/8/23)

CQCS3 Chinese Simplified Software Download (CQCS3 Download) (Update Date: 2017/07/21)

CQCS3 English software download (CQCS3 download) (Update date: 2017/07/21)

GQC6 Software Download for Gloss Meter PC (GQC6 Download) (Update Date: 2018/9/19)

NH310 USB driver download (USB driver NH310) (This driver may be misidentified as a virus by antivirus software, please rest assured to download!)

NH300 USB driver download (USB driver NH300) (This driver may be misidentified as a virus by anti-virus software, please rest assured to download!)

NH310 64-bit USB driver download (X64 USB driver NH310) (This driver may be misidentified as a virus by antivirus software, please rest assured to download!)

NH300 64-bit USB driver download (X64 USB driver NH300) (This driver may be misidentified as a virus by antivirus software, please rest assured to download!)

HYRes3.1 resolution test software download

Part 2: Download the full range of color card electronic versions

TCX Color Card Online Version: http://shop.3nh.com/product-203.html

TPX color card online version: http://shop.3nh.com/product-202.html

TPX color card 175 new colors online version: http://www.3nh.com/news/45.html

CU Color Card Online Version: http://www.3nh.com/news/47.html

TCX TPX latest color number, page number comparison table (make online version search very convenient)

(If your computer cannot extract the installation and download version, please check the online version directly)

TPX color card electronic version download

PANTONE CU Color Card Electronic Edition

Color card electronic version instructions

PANTONE PMS electronic version

Electronic version of RAL international color card

PANTONE? Card HD Picture

Pantone Glossy Coated Paper

PANTONE painted RGB

PANTONE color offset paper RGB

Pantone Color Lab and RGB with Hex

PANTONE CMYK

CUM color card electronic version download

Nippon Paint Color Card Electronic Edition

Electronic version of Dulux Color Card

Part III: Download of 3nh instrument instruction manual

Spectrophotometer Instruction Manual

YS45 series spectrophotometer manual

YS60 Series Desktop Spectrophotometer Instruction Manual

YS30 series spectrophotometer manual

Instruction Manual for NS808 Traffic Signpost Measurement Module

NS810 Spectrophotometer Instruction Manual

NS800 Spectrophotometer Instruction Manual

Color Difference Meter Instruction Manual

NH310 Portable Color Difference Meter Instruction Manual

NH300 Portable Color Difference Meter Instruction Manual

NR200 Portable Color Difference Meter Instruction Manual

NR60CP cost-effective precision colorimeter manual

NR110 cost-effective precision colorimeter manual

NR145 Cost-effective Precision Color Difference Meter Instruction Manual

NR20XE cost-effective precision colorimeter manual

NR10QC Color Difference Meter Instruction Manual

SC-10 Precision Color Difference Meter Manual

Gloss Meter Instruction Manual

NHG268 NHG60 NHG60M Gloss Meter Instruction Manual

HG268 HG60 HG60S Gloss Meter Instruction Manual

YG268 YG60 YG60S High Precision Gloss Meter Instruction Manual

电子捕鱼平台 网上棋牌手游大全 真钱二八杠 电玩城游戏大厅 万鑫娱乐游戏 九五至尊网站是多少 中文电子游戏官网 龙8app官网 最火的捕鱼游戏 澳门网上境外赌博